logo
Hogar > productos >
Localizador de fallas del cable
>
Portable Cable Fault Locator System for Underground Cable Insulation Faults

Portable Cable Fault Locator System for Underground Cable Insulation Faults

Detalles del producto:
Place of Origin: Xi'an, Shaanxi, China
Nombre de la marca: XZH TEST
Certificación: ISO,CE
Model Number: 502A+503C+535-4TS+507
Información detallada
Place of Origin:
Xi'an, Shaanxi, China
Nombre de la marca:
XZH TEST
Certificación:
ISO,CE
Model Number:
502A+503C+535-4TS+507
Resaltar:

High Light

Resaltar:

portable cable fault locator

,

underground cable insulation tester

,

cable fault detection system

Trading Information
Minimum Order Quantity:
1 unit
Packaging Details:
wooden case
Delivery Time:
8-10 days
Payment Terms:
T/T
Supply Ability:
1000 sets /Year
Descripción de producto
XZH TEST Portable Cable Fault Location System

Accurate fault detection system for underground cable main insulation faults

Portable Cable Fault Locator System for Underground Cable Insulation Faults 0
System Functionality
  • Uses DC or high-voltage pulse to make cable fault points flash over and discharge
  • Employs traveling wave reflection principle for rough measurement of cable faults
  • Utilizes acoustic-magnetic synchronization method for precise measurement of insulation faults
High Voltage Surge Generator XHHV535-4T
Output mode DC, Single, Cycle
Output voltage 0-8kV/0-16kV/0-32kV, three voltage switchable
Built-in capacitor 64μF/16μF/4μF
Discharge energy 2048J
Impact power 2000VA
Impulse rate Automatic impact for about 6 seconds, manual impact for any control time
Safety features Zero start protection, automatic discharge, over-voltage/current/heat protection (IP54 rating)
Dimensions 534L×444W×805H mm
Weight Not more than 120kg
TDR Cable Fault Locator XHGG502A
Test methods Low voltage pulse, Impulse current, Impulse voltage, ARC multiple pulse
Sampling rate 1MHz~400MHz
Measurement scope ≥120km
Minimum resolution 0.07m
Measurement error ≤±(0.5%×L+1m), L is cable length
Operating conditions -25℃~+65℃, 85% humidity, 750±30mmHg pressure
Cable Fault Pinpointer XHDD503C
Fixed-point modes Standard, enhanced, noise reduction, custom (ms, waveform)
Positioning accuracy 0.1m for both fixed point and path
Display 5-inch TFT (800×480 true color)
Gain 120dB (auto/manual adjustment)
Working time More than 8 hours on 4*18650 lithium batteries
Weight Host 0.6kg; Sensor 1.4kg
Test Cables

Note: Special high voltage cables required due to 35kV operation - keep away from site during operation.

  • High voltage output cable: 2.5mm² core (red), 50kV DC rating, shielded, 14mm outer diameter, 10m length with large spool
  • Ground cable: 3-column grounding (16mm² main core, 2.5mm² branch), 10m length with small spool
System in Operation