logo
Hogar > productos >
Localizador de fallas del cable
>
35kV Cable Fault Locator and Cable Sheath Fault Detector for Outer Sleeve Failure

35kV Cable Fault Locator and Cable Sheath Fault Detector for Outer Sleeve Failure

Detalles del producto:
Lugar de origen: La ciudad de Xi'an Shaanxi
Nombre de la marca: XZH TEST
Certificación: ISO CE
Número de modelo: XHHG520
Información detallada
Lugar de origen:
La ciudad de Xi'an Shaanxi
Nombre de la marca:
XZH TEST
Certificación:
ISO CE
Número de modelo:
XHHG520
Resaltar:

High Light

Resaltar:

Outer Sleeve Failure Cable Fault Locator

,

Cable Sheath Fault Detector

,

35kV Cable Fault Locator

Trading Information
Cantidad de orden mínima:
1 juego
Detalles de empaquetado:
Envasado de madera
Tiempo de entrega:
5-8 días laborables
Condiciones de pago:
T/T
Capacidad de la fuente:
3000 unidad/año
Descripción de producto
XHHG520
The Cable Fault Locator is designed for precise detection of outer sleeve failures in cables, providing accurate fault location to minimize downtime and maintenance costs.
The equipment uses an electric voltage regulator and an R-type transformer to form a high-voltage constant current source, with keypad operation for voltage increase and decrease. The open-circuit voltage is 15kV, and the short-circuit current is 100mA. A high-sensitivity amplifier and galvanometer indicate balance, forming a balanced bridge with a proportional potentiometer, and the entire unit is positioned at a high potential. The measuring cable is a specially designed double-core high-voltage rubber cable, and a four-terminal resistance measurement method is used to avoid errors introduced by lead resistance. The entire panel is positioned at a low potential. One-button operation allows for automatic calculation of the cable length and fault distance. The high-voltage source and bridge are integrated into a portable protective case. Therefore, this equipment features high voltage, light weight, convenient operation, and safe use.
Key Features
  • Accurate detection of outer sleeve failures
  • Precise fault location capabilities
  • Designed for efficient cable maintenance
  • Reduces system downtime and repair costs
Technical Specifications
Bridge Section Open-circuit voltage  ≥15kV

Short-circuit current  ≥100mA (recommended setting: 5~40mA during balancing)

Positioning ratio  accuracy ±(0.2%·L±1) meters
Voltage and Positioning Section Input voltage 220V (±10%), 50Hz (±2Hz)

Output voltage 0~15kV (square wave) adjustable

Output current 0~200mA

Output capacity 2kVA